Wissen

Wiederverwendbare Trockeneisbeutel: 2025 Komplette Anleitung

How to Use Reusable Dry Ice Packs in 2025

Aktualisiert: September 2, 2025. If you ship frozen goods, reusable dry ice packs can cut hazards, kosten, and complexity. They hold steady at sub‑zero targets without CO₂ off‑gassing, avoid UN1845 labels, and fit −15 °C to −25 °C lanes. Below you’ll learn how they work, how to size them, what rules apply, and where dry ice still wins.

reusable dry ice packs

  • What are reusable dry ice packs and how do they work? Sub‑zero PCMs explained for frozen shipping −20 °C/−25 °C.

  • When should you choose reusable dry ice packs vs. Trockeneis? Decision matrix for PCM vs dry ice Gassen.

  • How do you size and condition packs correctly? A copy‑and‑paste how to size PCM for frozen checklist and calculator.

  • Are they air‑legal and what labels apply? Dry ice label UN1845 net kg vs. “no DG label” for PCMs.

  • Was hat sich verändert 2025? −21 °C/−25 °C trends and sustainability signals you can act on now.


What are reusable dry ice packs and why now?

Reusable dry ice packs are sub‑zero phase‑change gel packs that hold a steady −20 °C to −25 °C plateau through many freeze–thaw cycles. They’re non‑hazardous, can touch product, and don’t require UN1845/Class 9 labels because they are not dry ice. Freeze them to their stated melt point (Z.B., −25 °C for −25 °C packs) to unlock full capacity.

Think of each pack as a rechargeable “cold battery.” You “charge” it to its melt point; as it absorbs heat, it melts at that temperature, keeping your payload cold and predictable. That gives you frozen control without dry ice’s venting and paperwork—ideal for diagnostics, Tiefkühlkost, and specialty pharma that target < −15 °C or < –20 ° C..

Which melt point fits your job (−20 °C vs −25 °C)?

Choose the melt point by spec and route. −20 °C packs suit “keep < −15 °C” lanes; −25 °C adds headroom for “keep < −20 °C.” Dry ice (–78,5 ° C.) is still the tool for ultra‑cold or multi‑day holds. Always charge to melt point—−18 °C freezers won’t fully charge −25 °C packs.

Option Typical Melt Point Charge Requirement Was bedeutet dies für Sie
−20 °C PCM pack –20 ° C. Freeze to ≤ −20 °C Meets < −15 °C lanes
−25 °C PCM pack −25 °C Freeze to ≤ −25 °C Tighter < −20 °C control
Trockeneis (Co₂, solide) –78,5 ° C. No pre‑freeze Ultra -cold, needs UN1845

Practical tips and cautions

  • Match melt point to lane to avoid over‑ or under‑cooling.

  • Charge fully to the actual melt point; partial charges shorten hold time.

  • Simplify labels: PCMs need no UN1845/Class 9 marks in air cargo.

Feldfall: A diagnostics lab swapped dry ice for −25 °C PCMs on overnights and held < −20 °C through morning pickups, with fewer carrier refusals and no DG handling.


How to size and condition reusable dry ice packs?

Size by thermal load, not box size. Start with 1–1.2 kg of −25 °C PCM per 5 L payload per 24 h, then adjust for insulation and ambient heat. Freeze packs to melt point (Z.B., −25 °C), pre‑chill product and shipper, and pack symmetrically with minimal air gaps.

You can picture your box as a leaky thermos—bigger boxes, hotter trucks, and lid openings “drain” your cold battery faster. Pre‑chilling shrinks day‑one losses; a fully charged −25 °C pack absorbs heat at −25 °C until it’s melted, giving you a flat, predictable profile.

Baseline per 24 h: −20 °C PCM = 1.0 kg / 5 L; −25 °C PCM = 1.2 kg / 5 L.
Formula: PCM kg = Baseline × (Duration/24) × Insulation × Ambient × (Payload L/5)
Tipp: place a logger near product core and validate on your lane before scaling.

Packout element What good looks like Warum ist es wichtig Für dich
Charging Freeze to melt point (Z.B., −25 °C) Full latent capacity Don’t rely on −18 °C freezers
Platzierung Packs on all sides; no big air gaps Even heat sink Avoid warm corners
Barriere Sheet between packs and labels Less condensation scuff Cleaner labels, fewer returns
Data logging Logger near product core Proof of control Audit‑ready history

Quick conditioning checklist

  1. Confirm lane target and duration.

  2. Pick −20 °C or −25 °C PCMs.

  3. Einfrieren to the stated melt point.

  4. Pre‑chill shipper & payload.

  5. Pack symmetrically; Hohlräume füllen.

  6. Add logger; close and record charge state.

Real result: A meal‑kit brand replaced ~10 lb dry ice with four −25 °C bricks in a 20 L qualified shipper for 36 h routes, cutting DG steps and smoothing hub acceptance.


Are reusable dry ice packs allowed on flights—and what labels apply?

Ja. Wiederverwendbare Trockeneisbeutel (PCMs) are not “dry ice,” so no UN1845/Class 9 marks are required. True dry ice needs proper shipping name, UN1845, net kg on the outer pack, and venting. Passengers with dry ice are capped at 2.5 kg mit Zustimmung der Fluggesellschaft; packages must vent.

Do this in practice:

  • For PCM shipments: mark normally; no DG declaration (check carrier house rules).

  • For dry ice: use “Dry ice/Carbon dioxide, solide" + UN1845 + Netz kg; ensure venting; follow IATA/FAA job aids.


PCM −20 °C vs −25 °C: which melt point is right for reusable dry ice packs?

Choose based on spec, box size, and time. −20 °C works for “keep < −15 °C” and small, kurze Gassen; −25 °C is better for “keep < −20 °C” or hotter ambients. Dry ice still covers ultra‑cold or long, bulky routes. For 2–8 °C meds, use +5 °C PCMs—not dry ice—to avoid freezing damage.

Decision matrix (fast pick)

Szenario Best choice Warum Watch‑outs
18–36H, halten < –15 ° C. −20 °C PCM Matches spec; wiederverwendbar Fully freeze packs
24–48H, halten < –20 ° C. −25 °C PCM Tighter plateau; contact‑safe Needs −25 °C freezer
48–96 h or ultra‑cold lanes Trockeneis Highest energy density UN1845 + Entlüftung
2–8 ° C (refrigerated products) +5 °C PCM Avoids freeze injury No dry ice/frozen gels

2025 trends in reusable dry ice packs and cold chain

Trend overview: Sub‑zero PCMs (−20 °C/−25 °C) continue to expand as dry‑ice alternatives in 2025, with more biodegradable gels, −21 °C options in EU lanes, and sharpened dry‑ice acceptance checklists that push shippers toward PCMs where feasible. ROI improves as DG hassle decreases.

Neueste Fortschritte auf einen Blick

  • Biodegradable −25 °C gels: modular panels for kit programs.

  • −21 °C PCM adoption: frozen food/diagnostics in Europe.

  • Policy clarity: UN1845/net‑kg/venting emphasized in 2025 checklists.

Market insight (plain English): PCMs don’t beat dry ice on sheer cold, but they often win on predictability, Einhaltung, and customer experience for −15 °C to −25 °C lanes—especially where DG steps slow you down.


Pro tips and user scenarios

  • Hot‑weather route: Use −25 °C packs on all sides, Hohlräume füllen, add top panel; log at 5‑min intervals.

  • Flight‑heavy lane: Prefer PCMs to avoid DG checks; if dry ice is required, label UN1845 + net kg and ensure venting.

  • Refrigerated biologics: Use +5 °C PCMs with proper conditioning; never pair dry ice with 2–8 °C vaccines.

Practical example: Overnight diagnostics in a qualified shipper with −20 °C packs maintained < −15 °C through morning pickup without DG labels—handled like standard express.


Lane fit self‑test (engagement tool)

Score your lane; higher scores suggest moving toward dry ice or hybrid.

  • Temperature target: < –20 ° C. (2); < –15 ° C. (1); 2–8 ° C (0)

  • Hold time: ≤ 36 h (1); 48–72H (2); > 72 H (3)

  • Payload size: ≤ 5 L (1); 6–20 L (2); > 20 L (3)

  • Isolierung: Qualified (1); Foam shipper (2); Soft tote (3)

  • Air transport constraints: Avoid DG preferred (2); DG okay (0)

Faustregel: 5–7 = PCMs likely ideal; 8–10 = pilot both; 11–13 = dry ice/hybrid.


FAQ: reusable dry ice packs

Q1: Are reusable dry ice packs actually “dry ice”?
NEIN. They are PCMs with defined melt points (Z.B., −20 °C or −25 °C) and do not off‑gas CO₂ or require UN1845 labels.

Q2: What freezer do I need for −25 °C packs?
Use a commercial freezer capable of −25 °C oder unten; −18 °C won’t fully charge a −25 °C pack.

Q3: Can I fly with reusable dry ice packs?
Ja. They are not dry ice. For dry ice, FAA caps passengers at 2.5 kg mit Zustimmung der Fluggesellschaft; packages must vent and be marked.

Q4: Do reusable packs work for 2–8 °C meds?
Verwenden +5 °C PCMs; avoid dry ice/frozen gels to prevent freezing injury.

Q5: Are there −21 °C options?
Ja. −21 °C PCMs are common in EU packaging lines as dry‑ice substitutes. Match melt point to your spec.


Zusammenfassung & Empfehlungen

Wiederverwendbare Trockeneisbeutel provide predictable frozen control for −15 °C to −25 °C lanes without DG labels or CO₂ hazards. Size by thermal load, charge to melt point, and validate with data logging. Keep dry ice for ultra‑cold or multi‑day holds, or use hybrids when needed. Aktionsplan: map lanes, choose −20 °C/−25 °C PCMs, pilot two packouts with loggers, refine mass, and maintain a dry‑ice contingency for edge cases.


Über Tempk

We’re a cold‑chain packaging and analytics team focused on validated, lane‑specific packouts. We pair qualified shippers with the right coolants—PCMs or dry ice—to hit your temperature targets with fewer touchpoints and lower landed cost. Strengths: evidence‑based SOPs and fast pilot‑to‑scale across DTC food, diagnostics, and specialty pharma. Ready to validate your lanes? Talk to a Tempk specialist for a free PCM vs. dry‑ice comparison.

Vorherige: Shipping Dry Ice Pack Sheet: 2025 Compliant Guide Nächste: Kleine Trockeneisbeutel: 2025 Größe, Sicherheit & Sops