Ice Pack Like Dry Ice: How to Choose and Size in 2025
If you need an ice pack like dry ice, pick PCM packs set to your target temperature (0–5°C, –15°C, –20/–26°C, or ~–70°C) and size them with a simple calculator for 24–120 hours. You’ll get safer handling, reusable cooling, and legal compliance for flights and parcel shipping—without hazmat headaches. Two quick facts: passenger air rules cap dry ice at 2.5 kg per package, and chilled food should stay at ≤4 °C.
-
Lequel ice pack like dry ice fits 2–8°C, frozen, or ~–70°C lanes? (dry ice alternative, PCM ice pack)
-
How do you size an ice pack like dry ice for 24–120 hours? (–20°C ice pack, calculatrice)
-
Can you fly with an ice pack like dry ice dans 2025? (ice pack like dry ice for flights)
-
When is dry ice still better—and how do you stay compliant? (–70°C shipping without dry ice)
What does an ice pack like dry ice actually mean in 2025?
Réponse courte: it’s a sealed PCM (phase‑change material) or gel pack tuned to a melting point that matches your lane. You choose the setpoint—0–5°C, –15°C, –20/–26°C, or ~–70°C—and avoid CO₂ venting, risque de gel, and hazmat labels. Use real dry ice only when you truly need –65 to –80 °C for longer than PCM can hold.
Why this matters: most “dry ice packs” are not carbon dioxide. They are reusable refrigerant packs that hold a narrow temperature and stay stable without venting. For food and many biologics, 0–5 °C packs protect quality. Pour les aliments surgelés, –15/–26 °C packs keep product below 0 °F. For deep‑frozen use, new ~–70 °C PCM + VIP (vacuum insulated) systems can replace CO₂ for limited durations.
Which setpoint should your ice pack like dry ice target?
Pick the setpoint based on product limits and route time. Chilled items prefer 0–5 °C to avoid cold shock. Frozen meat or pastries ride well at –15/–20/–26 °C. Specialized lab lanes can use ~–70 °C PCM + VIP for short deep‑cold windows. Validate once on your lane, then standardize the packout.
Cooling Option | Setpoint | Utilisation typique | Ce que cela signifie pour vous |
---|---|---|---|
0–5 °C gel/PCM | 0–5 °C | 2–8 °C food/biologics | No hazmat. TSA‑friendly if frozen solid. |
–15 °C PCM | –15 °C | Frozen pastries/meat | “Freezer‑like” without CO₂; pre‑freeze 24–36 h. |
–20/–26 °C PCM | –20 to –26 °C | True frozen lanes | Often marketed as a dry ice alternative. |
~–70 °C PCM + VIP | ≈–70 °C | Deep‑frozen, short haul | Dry‑ice‑free for limited durations (Par exemple, ~72 h). |
Glace sèche (Co₂) | –78,5 ° C | Ultra‑cold, longest | Ventilation + étiquettes; 2.5 kg passenger/package limit. |
Practical tips and quick wins
-
Precondition fully: freeze –15 °C PCM for 24–36 h at setpoint. Under‑charged packs underperform.
-
Pack tight: remplir les vides; air gaps are heat leaks.
-
Create zones: buffer delicate items from the coldest surfaces.
-
Verify: add a simple min/max thermometer inside the payload cavity.
Cas réel: A bakery shipped laminated dough with –15 °C PCM on sides/top and a thin 0 °C buffer near delicate layers. After ~30 h in summer heat, center stayed below –12 °C and cartons arrived dry and intact.
How do you size an ice pack like dry ice for 24–120 hours?
Use a fast estimator and adjust for conditions. For 2–8 °C runs with 0 °C gel/PCM, a ~1 kg pack often supports ~1–2 kg payload per 24 h in a decent shipper. For frozen (–15/–20/–26 °C), plan ~25–40% more PCM mass than chilled to cover the higher temperature lift. Pilot on your lane once, then lock the SOP.
Why the estimator works: water‑based gels deliver ~334 kJ/kg at melt, and PCM holds temperature tightly around its setpoint. Hot lanes, frequent openings, and weak insulation increase needs; shaded routes and VIP liners reduce them. Build in margin for weekends and handoffs.
Instant estimator (copy/paste)
Output: ≈ number of 1 kg gel/PCM packs
ConditionsFactor: 0.8 (cold/shade), 1.0 (normal), 1.3–1.5 (hot or frequent opens)
Frozen tweak: add ~25–40% PCM vs. chilled estimate.
Scénario | ConditionsFactor | Typical Add‑Ons | Ce que cela signifie pour vous |
---|---|---|---|
Overnight, temperate | 0.8–1.0 | Tight packout, lid blanket | Fewer packs; lower cost. |
48–72 h, summer | 1.3–1.5 | VIP liner, more top packs | Add 30–50% mass for heat load. |
Deep‑frozen ~–70 °C | lane‑specific | VIP + dedicated PCM set | Validate with a data logger. |
Can you fly with an ice pack like dry ice dans 2025?
Yes for gel/PCM if frozen solid at screening; partially melted packs follow standard liquids rules unless medically necessary. If you use actual dry ice, most passenger rules cap it at 2.5 kg per package and per passenger and require vented packaging plus clear “Dry ice/Carbon dioxide, solid” marking with net mass.
Carry‑on checklist for flights
-
Freeze packs rock‑solid and place them at the bottom.
-
Expect secondary screening if any pack turns slushy.
-
For medical need, declare at security.
-
If using real dry ice, ensure venting and airline approval; mark net mass.
Mode | Limit/Rule | Key Requirement | Ce que cela signifie pour vous |
---|---|---|---|
Gel/PCM | Frozen solid | Standard screening | No hazmat labels; smooth travel. |
Glace sèche | ≤2.5 kg/package & passenger | Ventilation + “Dry ice” + masse nette | Plan ahead; airline approval needed. |
When is an ice pack like dry ice better—and when is CO₂ still right?
Choose an ice pack like dry ice for 2–8 °C, –15 °C, and most –20/–26 °C lanes, especially where safety, réutilisation, and airline simplicity matter. Use CO₂ dry ice for the longest holds or when –65 to –80 °C is mandatory and PCM capacity falls short. In all cases, protect products from cold shock and monitor with a thermometer.
Safety and product quality basics
-
Dry ice releases CO₂ gas; avoid airtight containers and ensure ventilation.
-
Chilled foods should remain at ≤4 °C; frozen items at ≤–18 °C.
-
A small in‑box thermometer eliminates guesswork and supports QA.
2025 trends: ice pack like dry ice solutions and market shifts
Quoi de neuf: deep‑cold PCM systems now hold ~–70 °C without dry ice for limited durations (often around 72 h depending on model and route). Reusable VIP + PCM parcels are scaling across food and life sciences, and teams are standardizing “dry‑ice‑free” SOPs to cut hazmat overhead. Expect continued migration away from CO₂ on frozen lanes due to cost, sécurité, and sustainability goals.
Dernier progrès en un coup d'œil
-
~–70 °C without CO₂: PCM + VIP platforms target short deep‑cold lanes.
-
Sub‑zero without hazmat: –15/–26 °C PCM packs reduce dependency on CO₂.
-
Smart reusables: trackable, recyclable PCM “bricks” and validated packouts.
Perspicacité du marché: reusable systems and PCM are expanding across e‑commerce food and biopharma, reducing operating complexity and waste—while keeping compliance simpler for global shipments.
Questions fréquemment posées
1) What is the best ice pack like dry ice for meat shipping?
Use –15 °C for “freezer‑like,” or –20/–26 °C PCM for “true frozen.” Pre‑freeze product and packs, remplir les vides, and log temperatures.
2) Can an ice pack like dry ice replace dry ice at ~–70 °C?
Yes for limited durations with PCM + VIP; validate your exact route time and ambient profile before switching.
3) What’s the quickest way to size my ice pack like dry ice?
Use the estimator here, then add 30–50% for summer or frequent openings; pilot once with a data logger.
4) Can I fly with an ice pack like dry ice?
Gel/PCM: yes, when frozen solid at screening. Real dry ice: ≤2.5 kg/package and proper venting/marking; airline approval applies.
5) Do PCM packs need venting or special labels?
Non. They don’t vent gas and are not hazmat; standard shipping and storage apply.
6) What temperatures are “safe” for food shipments?
Keep chilled at ≤4 °C and frozen at ≤–18 °C; verify with an in‑box thermometer.
Résumé & recommendations
Points clés: choose an ice pack like dry ice by setpoint (0–5 °C, –15 °C, –20/–26 °C, ~–70 °C), size with the estimator, and validate once on your lane. Use dry ice only when ultra‑cold or very long holds demand it, then vent and label correctly. Monitor temperatures inside the payload cavity for QA and food safety.
Action plan:
-
Define your target temperature and duration.
-
Select PCM setpoint (or dry ice when mandatory).
-
Apply the estimator; add margin for heat and handling.
-
Pack tight, precondition fully, and place a thermometer at the core.
-
Standardize your SOP and train the team. Ready to optimize? Contact Tempk for a free packout review.
À propos du tempk
We design packout playbooks and calculators for perishable food, biopharma, and specialty goods. Our guidance reflects current airline, transport, and food‑safety rules and the latest PCM/VIP options—so you ship conforme, cost‑effective, and greener from day one. We test on real routes and publish brand‑agnostic templates your team can deploy now. Talk to a Tempk cold‑chain specialist—book a free consultation.