100L VPU Medical Cooler Box for Qualified Cold Chain Packouts

Tempk VIP and VPU medical cooler range

100L VPU Medical Cooler Box for Qualified Cold Chain Packouts

A 100L VPU medical cooler box for buyers planning larger temperature-sensitive medicine, vaccine, diagnostic sample or clinical supply shipments with a qualified coolant layout and temperature monitoring process.

Product format Large passive medical cooler box with VPU/VIP insulation planning
Reference capacity 100L from the existing product page
Use with Gel packs, ice bricks, PCM packs, dividers and temperature data loggers
Best suited for Bulk pharma cartons, vaccine programs, clinical supplies and monitored medical cold chain routes
Watch Product Video

Large VPU medical cooler box for monitored route trials

This 100L medical cooler box gives project teams a larger passive shipper for bulk healthcare payloads. The box should be matched with coolant, payload mass, route duration, ambient exposure and a monitoring plan before routine medical use.

100L working volume

The larger capacity supports bulk cartons, sample kits or medical supply loads where a small carrier is not enough.

Passive insulation structure

VPU/VIP insulation helps reduce heat gain when it is paired with the correct coolant system.

Monitoring-ready packout

The internal layout can reserve space for data loggers or route monitors when the shipment requires traceability.

Coolant layout flexibility

Use gel packs, ice bricks or PCM packs according to target temperature, payload and route duration.

Custom project setup

Tempk can support size, logo, labels, dividers, carton packing and route-trial samples.

Reusable program fit

The box can be planned for return, cleaning, inspection and redeployment in controlled logistics programs.

Product details

Product type 100L VPU medical cooler box
Capacity Reference 100L
Insulation approach VPU/VIP passive insulation structure from the existing product family
Coolant options Gel ice pack, ice brick, PCM pack or combined coolant layout
Monitoring Compatible with temperature monitoring plans selected by the shipper
Customization Size, label, logo, divider, coolant position, carton and accessory options by project

Where it fits best

Pharma distribution

For larger medicine or clinical supply shipments where packaging qualification is required before routine use.

Vaccine and biologic programs

For refrigerated or controlled-temperature routes when the full packout is validated with coolant and monitoring.

Medical sample logistics

For diagnostic sample programs that need larger payload space and documented handling steps.

How to plan the packout

Define the temperature window

Confirm the required range, such as 2-8 C or another project specification, before choosing coolant.

Map route exposure

Review transit time, vehicle staging, handoff points, ambient profile and expected lid-open risk.

Build the coolant layout

Place coolant and payload in a repeatable pattern, leaving room for monitors where required.

Run qualification trials

Test the box, coolant, payload and route profile before using the packout for routine healthcare shipments.

Customization support

Payload layout

Plan dividers, inserts, sample racks, liners or coolant positions around the 100L volume.

Program identification

Add project labels, QR codes, route marks, logo or handling instructions.

Trial support

Request sample units, accessory kits and packing notes for route qualification work.

Handling instructions

Pre-condition coolant according to the route protocol. Load the payload, coolant and temperature monitor in the tested positions, then close the lid fully and keep the box away from unnecessary ambient exposure during staging.

For pharmaceutical, vaccine or clinical sample use, qualify the complete packout with the real payload mass, coolant quantity, route duration and ambient profile before routine shipment.

Features

  • 100L working volume
  • Passive insulation structure
  • Monitoring-ready packout
  • Coolant layout flexibility
  • Custom project setup
  • Reusable program fit

Product video

Request packout support

  • Payload type, carton dimensions, payload mass and target temperature window
  • Route duration, ambient exposure, handoff steps and monitor requirement
  • Coolant type, PCM phase point, divider, label and accessory needs
  • Sample quantity, validation plan, monthly volume and packing method

FAQ

Can this 100L cooler box be used for 2-8 C shipments?

It can be planned for refrigerated medical routes only after the complete box, coolant, payload and route profile are qualified against the required temperature window.

Does the box control temperature by itself?

No. It is a passive insulated box. The coolant system, payload mass, monitor placement and route exposure determine the final packout result.

Can a data logger be used inside the box?

Yes. Medical shipments often include a data logger or monitor, and the placement should be part of the tested packout procedure.

Can Tempk customize the 100L medical cooler box?

Yes. Tempk can support size, label, logo, divider, coolant position, carton packing and sample preparation for project trials.

Related product tags

Get a Quote